Title of article :
Potential difference caused by humidity and temperature gradients in a proton-exchange membrane
Author/Authors :
Siroma، نويسنده , , Zyun and Fujiwara، نويسنده , , Naoko and Ioroi، نويسنده , , Tsutomu and Yamazaki، نويسنده , , Shin-ichi and Senoh، نويسنده , , Hiroshi and Yasuda، نويسنده , , Kazuaki، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
As a factor that may affect the accuracy of the measurement of electrode potentials in proton-exchange membrane fuel cells, the potential difference in a strip of Nafion® 117 membrane induced by a humidity or temperature gradient was examined. The sample was placed in a cell with two chambers, where the temperature and humidity could be controlled individually. Hydrogen gas was fed to both chambers, and the voltage between two electrodes set at the ends of the sample, which acts as a reversible hydrogen electrode, was measured. A higher potential of the electrode was observed when humidity or temperature was set lower than the other electrode.
Keywords :
proton exchange membrane , Potential distribution , Streaming potential , Thermoelectromotive force , Reference electrode
Journal title :
Journal of Electroanalytical Chemistry
Journal title :
Journal of Electroanalytical Chemistry