Title of article :
Low energy hydrogen sensor
Author/Authors :
Linke، نويسنده , , S. and Dallmer، نويسنده , , M. and Werner، نويسنده , , R. and Moritz، نويسنده , , W.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
6
From page :
17523
To page :
17528
Abstract :
A new silicon-based hydrogen sensor for measurements at high concentrations near the lower flammable limit of hydrogen (40,000 ppm) is presented. Due to operation at room temperature the power consumption of the sensor is smaller than that of other sensors on the market by several orders magnitude. Further development of the sensor system could lead to battery powered or even energy-independent operation. As sensor fabrication is based on semiconductor technology, low-cost production can be achieved for the mass market. The sensor investigated showed good long-term stability combined with a fast response on the basis of cyclic thermal activations. This was demonstrated by a stress test that simulated the activation and measurement cycles experienced by the sensor in one year. Finite element method was used to further reduce the power consumption of the thermal activation. This resulted in an average power consumption of 2 × 10−6 W for the sensor activation.
Keywords :
Hydrogen sensor , low energy , MIS structure , Proton-conducting solid electrolyte
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2012
Journal title :
International Journal of Hydrogen Energy
Record number :
1673914
Link To Document :
بازگشت