• Title of article

    Electrochemically pretreated screen-printed carbon electrodes for the simultaneous determination of aminophenol isomers

  • Author/Authors

    Su، نويسنده , , Wan-Yu and Wang، نويسنده , , Sheng-Ming and Cheng، نويسنده , , Shu-Hua، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    166
  • To page
    172
  • Abstract
    This study reports that disposable, electrochemically pretreated screen-printed carbon electrodes (SPCE*) can be employed for the simultaneous determination of aminophenol isomers in aqueous buffer solution. In sharp contrast to untreated SPCE, voltammetric studies indicate that the oxidation peak potential of each analyte in an aminophenol isomer mixture may be separated at the activated SPCE*. The individual oxidation peak currents are greatly increased by first-order derivative techniques. All experimental parameters were optimized to improve responses. The derivative oxidation peak currents is proportional to the concentration of isomer over the range from 0.2 to 100 μM for 2-aminophenol (2AP), from 3.0 to 200 μM for 3-aminophenol (3AP), and from 0.2 to 200 μM for 4-aminophenol (4AP), with detection limits of 0.07, 0.16 and 0.05 μM, respectively. The proposed methods have excellent analytical characteristics that include ease of handling, high sensitivity, wide linear dynamic range and low detection limits. The assay was applied to the simultaneous determination of aminophenol isomers in river water with good recovery results.
  • Keywords
    Simultaneous voltammetric determination , First-order derivative techniques , Electrochemical pretreatment , aminophenol isomers , Disposable screen-printed carbon electrode
  • Journal title
    Journal of Electroanalytical Chemistry
  • Serial Year
    2011
  • Journal title
    Journal of Electroanalytical Chemistry
  • Record number