Title of article :
Voltammetric and impedimetric detection of DNA hybridization by using dendrimer modified graphite electrodes
Author/Authors :
Mese، نويسنده , , Fehmi and Congur، نويسنده , , Gulsah and Erdem، نويسنده , , Arzum، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
6
From page :
92
To page :
97
Abstract :
In the present study, the electrochemical sensor was designed by the modification of the fourth generation poly(amido amine) (PAMAM) dendrimer onto the surface of pencil graphite electrode (G4-PDR/PGE) and this single-use dendrimer modified electrode was then examined for advanced nucleic acid detection by using electrochemical techniques. After the covalent immobilization of G4-PDR onto the surface of carboxylated PGE surface, the surface characterization of dendrimer modified PGE was investigated by using scanning electron microscopy (SEM), and also, different electrochemical techniques; cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The voltammetric monitoring of a sequence-selective DNA hybridization related to Hepatitis B virus (HBV) sequences was accordingly performed in the presence of the complementary of probe (target), and also the mixture medium containing target:non-complementary (NC) sequences (1:1).
Keywords :
PAMAM dendrimer , DNA biosensor , Cyclic voltammetry , Pencil graphite electrode , Electrochemical impedance spectroscopy
Journal title :
Journal of Electroanalytical Chemistry
Serial Year :
2014
Journal title :
Journal of Electroanalytical Chemistry
Record number :
1678111
Link To Document :
بازگشت