Title of article :
Spectral and non-spectral interferences in the determination of thallium in environmental materials using electrothermal atomization and vaporization techniques—a case study
Author/Authors :
Vale، نويسنده , , Maria Goreti R. and Welz، نويسنده , , Bernhard، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
14
From page :
1821
To page :
1834
Abstract :
The literature on the determination of Tl in environmental samples using electrothermal atomization (ETA) and vaporization (ETV) techniques has been reviewed with special attention devoted to potential interferences and their control. Chloride interference, which is due to the formation of the volatile monochloride in the condensed phase, is the most frequently observed problem. Due to its high dissociation energy (88 kcal/mol), TlCl is difficult to dissociate in the gas phase and is easily lost. The best means of controlling this interference in ETA is atomization under isothermal conditions according to the stabilized temperature platform furnace concept, and the use of reduced palladium as a modifier. An alternative approach appears to be the ‘fast furnace’ concept, wherein both the use of a modifier and the pyrolysis stage are omitted. This concept requires an efficient background correction system, and high-resolution continuum-source atomic absorption spectrometry (HR-CS AAS) appears to offer the best results. This chloride interference can also cause significant problems when ETV techniques are used. Among the spectral interferences found in the determination of thallium are those due to Pd, the most efficient modifier, and Fe, which is frequently found at high concentrations in environmental samples. Both interferences are due to nearby atomic lines, and are observed only when deuterium background correction and relatively high atomization temperatures are used. A more serious spectral interference is that due to the molecular absorption spectrum of SO2, which has a maximum around the Tl line and exhibits a pronounced rotational fine structure. HR-CS AAS again showed the best performance in coping with this interference.
Keywords :
Environmental samples , Thallium determination , Electrothermal atomic absorption spectrometry , Electrothermal vaporization inductively coupled plasma mass spectrometry , interferences
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Serial Year :
2002
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Record number :
1679379
Link To Document :
بازگشت