Title of article :
Chemical vapor generation of silver for atomic absorption spectrometry with the multiatomizer: Radiotracer efficiency study and characterization of silver species
Author/Authors :
Musil، نويسنده , , Stanislav and Kratzer، نويسنده , , Jan and Vobeck?، نويسنده , , Miloslav and Hovorka، نويسنده , , Jan and Benada، نويسنده , , Old?ich and Matou?ek، نويسنده , , Tom??، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
Volatile Ag species were generated in flow injection arrangement from nitric acid environment in the presence of surfactants (Triton X-100 and Antifoam B) and permanent Pd deposits as the reaction modifiers. Atomic absorption spectrometry (AAS) with multiple microflame quartz tube atomizer heated to 900 °C was used for atomization; evidence was found for thermal mechanism of atomization. Relative and absolute limits of detection (3σ, 250 μl sample loop) measured under optimized conditions were: 1.4 μg l− 1 and 0.35 ng, respectively.
ficiency of chemical vapor generation (CVG) as well as spatial distribution of residual analyte in the apparatus was studied by 111Ag radioactive indicator (half-life 7.45 days) of high specific activity. It was found out that 23% of analyte was released into the gaseous phase. However, only 8% was found on filters placed at the entrance to the atomizer due to transport losses. About 40% of analyte remained in waste liquid, whereas the rest was found deposited over the CVG system.
ted study follows the hypothesis that the “volatile” Ag species are actually metallic nanoparticles formed upon reduction in liquid phase and then released with good efficiency to the gaseous phase. Number/charge size distributions of dry aerosol were determined by Scanning Mobility Particle Sizer. Ag was detected in 40–45 nm particles holding 10 times more charge if compared to Boltzmann equilibrium. At the same time, Ag was also present on 150 nm particles, the main size mode of the CVG generator. The increase of Ag in standards was reflected by proportional increase in particle number/charge for 40–45 nm size particles only.
ission electron microscopy revealed particles of 8 ± 2 nm sampled from the gaseous phase, which were associated in isolated clusters of few to few tens of nanometres. Ag presence in those particles was confirmed by Energy Dispersive X-ray Spectroscopy (EDS) analysis.
Keywords :
Atomic absorption spectrometry , Multiatomizer radiotracer , Chemical vapor generation , silver , Aerosol size distribution
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy