Title of article
Evaluation of Bi as internal standard to minimize matrix effects on the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru permanent modifier with co-injection of Pd/Mg(NO3)2
Author/Authors
de Oliveira، نويسنده , , Silvana Ruella and Neto، نويسنده , , José Anchieta Gomes، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
5
From page
1046
To page
1050
Abstract
Bismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)2. The correlation coefficient of the graph plotted from the normalized absorbance signals of Bi versus Pb was r = 0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve obtained from reference solutions prepared in 0.2% (v/v) HNO3 and analytical curves obtained from Pb additions in red and white wine vinegar samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analytical curves without. Analytical curves in the 2.5–15 μg L− 1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analyte concentration, and typical linear correlations of r = 0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 μg L− 1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 μg L− 1 and the relative standard deviation was ≤ 3.8% and ≤ 8.3% (n = 12) for a sample containing 10 μg L− 1 Pb with and without internal standard, respectively.
Keywords
Lead , vinegar , Graphite furnace atomic absorption spectrometry , Ru permanent modifier , Bismuth internal standard
Journal title
Spectrochimica Acta Part B Atomic Spectroscopy
Serial Year
2007
Journal title
Spectrochimica Acta Part B Atomic Spectroscopy
Record number
1682005
Link To Document