Title of article :
Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure
Author/Authors :
Fittschen، نويسنده , , U.E.A. and Meirer، نويسنده , , F. and Streli، نويسنده , , C. and Wobrauschek، نويسنده , , P. and Thiele، نويسنده , , J. and Falkenberg، نويسنده , , G. and Pepponi، نويسنده , , G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
7
From page :
1489
To page :
1495
Abstract :
In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence–X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0–8.0 μm, 8.0–2.0 μm, 2.0–0.13 μm 0.13–0.015 μm (aerodynamic particle size) and 15–30 nm, 30–60 nm, 60–130 nm, 130–250 nm, 250–500 nm, 0.5–1 μm, 1–2 μm, 2–4 μm, 4–8 μm, 8–16 μm. Prior to the sampling “bounce off” effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1–10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. sults from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. e determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in all particle size fractions.
Keywords :
Iron , SR-TXRF , TXRF-XANES , Aerosol analysis
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Serial Year :
2008
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Record number :
1682669
Link To Document :
بازگشت