Title of article :
Modelling the temporal intensity distribution of laser ablation inductively coupled plasma mass spectrometry in single shot mode
Author/Authors :
Gنckle، نويسنده , , M. and Merten، نويسنده , , D.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
13
From page :
1893
To page :
1905
Abstract :
A transport model is proposed that describes the temporal intensity distribution observed in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) in single-shot mode using quantitative signal equations. Calculations aim on the deduction of the dispersion function describing the time-dependent part of the signal equation. spersion function depends on transport time in the centre of the transport tube, as related to carrier gas flow rate and tube volume and on the relation between carrier gas flow rate and ablation chamber volume. The equations describing the signal shape standardize signals from different systems and allow quantitative optimization of the ablation chamber, the transport tube and the detector. ation of the model to ICP-MS shows that only a part of the area filled by the transported vaporization product and thus only a part of the transported vaporization product can be observed at the detector. The model is able to quantify both fractions. calculated, the observed fraction of analyte is always higher than the observed fraction of the sample containing cross section and depends on the chosen transport parameters characterising the dispersion function. Thus, the determination of the signal integrals in the usual way can lead to systematic errors if the parameters influencing the dispersion function are variable. ore, a different method of analysis based on signal equations is proposed and demonstrated. By this method of data treatment, all important system parameters influencing the dispersion function could be calculated and matched with theoretical ones. Furthermore, a complete integral of the transient signal including its statistical variation can be generated from a limited number of measurement points. For example, this can be applied to signals detected incompletely because of detector saturation and enables the use of high-abundance elements as internal standards. rmore, the method can be used to monitor system performance, to identify the flow regime inside the ablation chamber, to take into account the sample volume for quantitative analysis and finally, to detect anomalous signal distributions that would lead to systematic errors. The prospects and limitations of the model are discussed for LA-ICP-MS in single shot mode.
Keywords :
Transport model , Laser ablation , Quantitative signal equations , transient signals , Single shot mode , ICP-MS
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Serial Year :
2004
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Record number :
1686536
Link To Document :
بازگشت