Title of article :
Dithizone–chloroform single drop microextraction system combined with electrothermal atomic absorption spectrometry using Ir as permanent modifier for the determination of Cd in water and biological samples
Author/Authors :
Fan، نويسنده , , Zhefeng and Zhou، نويسنده , , Wei، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
5
From page :
870
To page :
874
Abstract :
A simple and sensitive method using dithizone–chloroform single drop microextraction has been developed for separation and preconcentration of trace Cd prior to its determination by electrothermal atomic absorption spectrometry with Ir as permanent modifier. Parameters, such as pyrolysis and atomization temperature, solvent type, pH, dithizone concentration, extraction time, organic drop volume, stirring rate and sample volume were investigated. Under the optimized conditions, a detection limit (3σ) of 0.7 ng/l and enrichment factor of 65 were achieved. The relative standard deviation was 7.4% (c = 0.2 μg/l, n = 5). The developed method has been applied to the determination of trace Cd in water samples and biological reference materials with satisfactory results.
Keywords :
Single-drop microextraction , Electrothermal atomic absorption spectrometry , CD , Permanent modifier
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Serial Year :
2006
Journal title :
Spectrochimica Acta Part B Atomic Spectroscopy
Record number :
1686781