• Title of article

    Determination of Te in soldering tin using continuous flowing electrochemical hydride generation atomic fluorescence spectrometry

  • Author/Authors

    Jiang، نويسنده , , Xianjuan and Gan، نويسنده , , Wuer and Han، نويسنده , , Suping and He، نويسنده , , Youzhao He، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    4
  • From page
    710
  • To page
    713
  • Abstract
    An electrochemical hydride generation system was developed for the detection of Te by coupling an electrochemical hydride generator with atomic fluorescence spectrometry. Since TeH2 is unstable and easily decomposes in solution, a reticular W filament cathode was used in the present system. The TeH2 generated on the cathode surface was effectively driven out by sweeping gas from the cathode chamber. In addition, a low temperature electrochemical cell (10 °C) was applied to reduce the decomposition of TeH2 in solution. The limit of detection (LOD) was 2.2 ng ml− 1 and the relative standard deviation (RSD) was 3.9% for nine consecutive measurements of standard solution. This method was successfully employed for determination of Te in soldering tin material.
  • Keywords
    Atomic fluorescence spectroscopy , TE , Electrochemical hydride generation
  • Journal title
    Spectrochimica Acta Part B Atomic Spectroscopy
  • Serial Year
    2008
  • Journal title
    Spectrochimica Acta Part B Atomic Spectroscopy
  • Record number