Title of article :
Mixing behavior of wide-size-distribution particles in a FCC riser
Author/Authors :
Liu، نويسنده , , Huiʹe and Wei، نويسنده , , Fei and Yang، نويسنده , , Yanhui and Jin، نويسنده , , Yong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
A comparison study on the axial and lateral mixing of wide-size-distribution (WSD) particles with normal-size-distribution (NSD) FCC particles is presented. The fines smaller than 20 μm contribute 24.5% in volume in the WSD particles. Phosphor tracer method is used. The axial backmixing of the WSD is slightly lower than the NSD. However, the lateral solids Peclet number increases linearly with the increase of the content of fines smaller than 20 μm because of the serious agglomeration of the fines, which leads to very poor lateral mixing for the WSD particles. And the solids lateral mixing for the WSD particles decreases significantly with increasing solids fraction. These results show that the particle size and the particle-size-distribution is a very important factor that controls the lateral solids mixing and hence the heat and mass transfer in lateral direction, which should be taken into full consideration in the riser reactor. And the NSD may be a good particle size distribution for the FCC riser, the lateral solids mixing of which is satisfactory in the reactor.
Keywords :
Wide-size-distribution , Normal-size-distribution , Riser , Axial and lateral solids mixing , Phosphor tracer
Journal title :
Powder Technology
Journal title :
Powder Technology