Title of article :
Dual fibre optical probe measurements of solids volume fraction in a circulating fluidized bed
Author/Authors :
Magnusson، نويسنده , , A. and Rundqvist، نويسنده , , R. and Almstedt، نويسنده , , A.E. and Johnsson، نويسنده , , F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
The calibration of a dual fibre optical probe was experimentally investigated in a circulating fluidized bed. The particle volume fraction registered by the optical probe was compared to pressure drop measurements for a range of operating conditions. A theoretical calibration theory was applied to the probe signal to obtain the local and instantaneous particle volume fraction. It was found that glare points on the particles and the beam length from the probe to the particle determines the curvature of the calibration function to a large extent.
Keywords :
Solids volume fraction , Circulating fluidized bed , Optical probe measurement
Journal title :
Powder Technology
Journal title :
Powder Technology