Title of article :
Self-calibration of hybrid central catadioptric and perspective cameras
Author/Authors :
Deng، نويسنده , , Xiaoming and Wu، نويسنده , , Fuchao and Wu، نويسنده , , Yihong and Duan، نويسنده , , Fuqing and Chang، نويسنده , , Liang and Wang، نويسنده , , Hongan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
15
From page :
715
To page :
729
Abstract :
Hybrid central catadioptric and perspective cameras are desired in practice, because the hybrid camera system can capture large field of view as well as high-resolution images. However, the calibration of the system is challenging due to heavy distortions in catadioptric cameras. In addition, previous calibration methods are only suitable for the camera system consisting of perspective cameras and catadioptric cameras with only parabolic mirrors, in which priors about the intrinsic parameters of perspective cameras are required. In this work, we provide a new approach to handle the problems. We show that if the hybrid camera system consists of at least two central catadioptric and one perspective cameras, both the intrinsic and extrinsic parameters of the system can be calibrated linearly without priors about intrinsic parameters of the perspective cameras, and the supported central catadioptric cameras of our method can be more generic. In this work, an approximated polynomial model is derived and used for rectification of catadioptric image. Firstly, with the epipolar geometry between the perspective and rectified catadioptric images, the distortion parameters of the polynomial model can be estimated linearly. Then a new method is proposed to estimate the intrinsic parameters of a central catadioptric camera with the parameters in the polynomial model, and hence the catadioptric cameras can be calibrated. Finally, a linear self-calibration method for the hybrid system is given with the calibrated catadioptric cameras. The main advantage of our method is that it cannot only calibrate both the intrinsic and extrinsic parameters of the hybrid camera system, but also simplify a traditional nonlinear self-calibration of perspective cameras to a linear process. Experiments show that our proposed method is robust and reliable.
Keywords :
Camera Calibration , Radial distortion , Central catadioptric camera , 3D imaging
Journal title :
Computer Vision and Image Understanding
Serial Year :
2012
Journal title :
Computer Vision and Image Understanding
Record number :
1696686
Link To Document :
بازگشت