Title of article :
Measurement of solid circulation rate in a circulating fluidized bed
Author/Authors :
Matsuda، نويسنده , , Satoru، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
5
From page :
200
To page :
204
Abstract :
A method using an optical mouse sensor was developed to monitor the moving velocity of a solid mass. Calibration was carried out using a rotating plate. Results clarified that the developed method is useful to monitor the velocity up to some limit (v < 0.3 m/s), which depends on the optical mouse sensor used. A solid circulation rate in a circulating fluidized bed (CFB) was measured using this method. Results obtained using this method show agreement with those of visual observations.
Keywords :
Solid circulation rate , CFB , Optical mouse sensor , Solid mass flux , Circulating fluidized bed