Title of article :
Method for characterization of loss-in-weight feeder equipment
Author/Authors :
Engisch، نويسنده , , William E. and Muzzio، نويسنده , , Fernando J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
9
From page :
395
To page :
403
Abstract :
This paper presents a method for evaluating the steady state performance of loss-in-weight powder feeding equipment and then demonstrates the use of the method in evaluating the performance of a K-Tron KT35 loss-in-weight feeder for three pharmaceutical grade powders. The method describes in detail the experimental setup, the procedure used in collecting feedstream data, and the filtering and subsequent analysis that is needed to determine differences in the steady state feeding performance. The data stream is shown to be a complex data set that can be simplified, after applying a suggested filtering and analysis algorithm, to two quantities (average feedrate and relative standard deviation) that can be used for comparison of different feeding treatments (powder, feeder tooling, and setpoint). Through analysis of variance (ANOVA), the significance of various tooling on optimizing feeder performance can be evaluated.
Keywords :
powders , FEEDRATE , Feeders , pharmaceutical , Gravimetric , Loss-in-weight
Journal title :
Powder Technology
Serial Year :
2012
Journal title :
Powder Technology
Record number :
1702166
Link To Document :
بازگشت