Title of article :
Reversed-phase liquid chromatographic column switching for the determination of N-methylcarbamates and some of their main metabolites in urine
Author/Authors :
Parrilla V?zquez، نويسنده , , J. L. Martinez Vidal، نويسنده , , J.L and Mart??nez Fern?ndez، نويسنده , , J، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
8
From page :
387
To page :
394
Abstract :
A column switching system for the determination of some polar pesticides and their main metabolites, such as aldicarb, aldicarb sulphoxide, aldicarb sulphone, carbofuran and 3-hydroxicarbofuran, in human urine has been developed. The limits of detection were between 0.3 and 1 μg/l. We used a simple solid-phase extraction with graphite carbon and a RPLC–LC analysis with UV detection yielding average recoveries between 84 and 110% (N=5) with RSD between 4 and 8%.
Keywords :
N-methylcarbamates
Journal title :
Journal of Chromatography B Biomedical Sciences and Applications
Serial Year :
2000
Journal title :
Journal of Chromatography B Biomedical Sciences and Applications
Record number :
1702942
Link To Document :
بازگشت