Title of article :
Development of a methodology to estimate error in the on-line measurements of blend uniformity in a continuous powder mixing process
Author/Authors :
Vanarase، نويسنده , , Aditya U. and Jنrvinen، نويسنده , , Maiju and Paaso، نويسنده , , Janne and Muzzio، نويسنده , , Fernando J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
9
From page :
263
To page :
271
Abstract :
In this paper, a multi-point fiber optic based NIR system was implemented to monitor API concentration at the discharge of a continuous mixer. The sample size being interrogated by NIR was determined by measuring the velocity of the powder on the chute, which allowed selection of the number of scans to be averaged. A methodology was developed that allows quantification of the error associated with the in-line measurements. Comparison of in-line and off-line measurements was made at equivalent sample sizes. Mathematical model fitting for the in-line as well as off-line data revealed that the contribution of the analytical method error was negligible. A baseline RSD of 0.02 in the in-line measurements persists because of the inherent non-uniform nature of powder material. These results are useful towards achieving Real-Time-Release (RTR) of continuously manufactured drug product.
Keywords :
Process analytical technology (PAT) , Continuous powder mixing , NIR (Near Infra-Red) spectroscopy
Journal title :
Powder Technology
Serial Year :
2013
Journal title :
Powder Technology
Record number :
1703716
Link To Document :
بازگشت