Title of article :
Development of a high-performance liquid chromatographic–tandem mass spectrometric method for the determination of pharmacokinetics of Co 102862 in mouse, rat, monkey and dog plasma
Author/Authors :
Ramu، نويسنده , , K. and Lam، نويسنده , , G.N. and Chien، نويسنده , , B.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
A method for determining concentration levels of Co 102862 in mouse, rat, monkey and dog plasma was validated in the range of 5 to 2000 ng/ml using 200 μl plasma sample volume. This validation report describes the linearity, specificity, sensitivity, reproducibility, accuracy, recovery and stability of the analytical method. The inter-day RSD ranged from 3.5 to 10.1%, intra-day RSD from 0.6 to 5.7% and intra-day accuracy (mean absolute percent difference) ranged from 2.2 to 14.9% for rat, monkey and dog plasma. A mini-validation (5–2000 ng/ml) of Co 102862 was performed in mouse plasma using the same methods. Additionally, the assay range at the low end was successfully extended to 0.5 ng/ml for monkey plasma. The method was used for the routine analysis of Co 102862 in mouse, rat, monkey and dog plasma and summary of the pharmacokinetic data are presented.
Journal title :
Journal of Chromatography B Biomedical Sciences and Applications
Journal title :
Journal of Chromatography B Biomedical Sciences and Applications