Title of article :
Applications of microelectrodes in impedance spectroscopy
Author/Authors :
Franz Pernkopf، نويسنده , , Walter and Sagl، نويسنده , , Markus and Fafilek، نويسنده , , Günter and Besenhard، نويسنده , , Jürgen O. and Kronberger، نويسنده , , Hermann and Nauer، نويسنده , , Gerhard E.، نويسنده ,
Issue Information :
هفته نامه با شماره پیاپی سال 2005
Pages :
6
From page :
2031
To page :
2036
Abstract :
Using a simple method for manufacturing of micro-tips, numerous microelectrodes with reasonably small electroactive area were produced by insulating the micro-tips into glass capillaries. Microelectrode characterisation was carried out with steady state diffusion limited current measurements in acidic FeCl3 solution. The microelectrodes were used for different purposes, the simplest of which was measuring the impedance in the region of a small conductive area placed in an insulating surrounding. Other measurements were carried out by generating impedance profiles in different electrolytes, as a microelectrode approached a conversion-coated metal surface, in order to gain information about the properties of the coating.
Keywords :
LEIS , Passive layer , Corrosion , Resistance mapping , Conversion coating , Local impedance
Journal title :
Solid State Ionics
Serial Year :
2005
Journal title :
Solid State Ionics
Record number :
1718047
Link To Document :
بازگشت