Title of article :
The microstructure and properties of commercial pure iron modified by plasma nitriding
Author/Authors :
Chen، نويسنده , , Chang-Zi and Shi، نويسنده , , Xinghua and Zhang، نويسنده , , Pengcheng and Bai، نويسنده , , Bin and Leng، نويسنده , , Yong-Xiang and Huang، نويسنده , , Nan، نويسنده ,
Issue Information :
هفته نامه با شماره پیاپی سال 2008
Pages :
4
From page :
971
To page :
974
Abstract :
This paper was concerned with commercial pure iron plasma nitride at different bias voltages by high frequency and low voltage plasma nitriding. The results showed that the microstructure of the nitride layers was strongly influenced by the bias voltages. Compared with − 1.5 kV and − 2.5 kV, the pure iron plasma nitriding at − 3.5 kV has the best wear resistance and corrosion resistance and its microhardness was three times than that of the virgin pure iron. The increase of bias voltage would promote the formation of the nitride layers. The nitride layer which is composed of epsiv-Fe2–3N iron nitride and gamma-Fe4N iron nitride was a key factor in the properties enhancement of the commercial pure iron, which was modified by high frequency and low voltage plasma nitriding.
Keywords :
microstructure , Iron nitride , Microhardness , Wear resistance , High frequency and low voltage plasma immersion and ion implantation (HLPIII) , CORROSION RESISTANCE
Journal title :
Solid State Ionics
Serial Year :
2008
Journal title :
Solid State Ionics
Record number :
1720651
Link To Document :
بازگشت