Title of article :
Consistent hydration of intervertebral discs during in vitro testing
Author/Authors :
Huber، نويسنده , , Gerd and Morlock، نويسنده , , Michael M. and Ito، نويسنده , , Keita، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
6
From page :
808
To page :
813
Abstract :
Spinal specimens are commonly sprayed with saline solution during mechanical testing to ensure adequate hydration. However, potting of vertebrae inhibits physiological fluid exchange through the porous endplates during loading. This un-physiological flow regime may influence mechanical properties of intervertebral discs and therefore of the whole spinal unit. jective of this study was to evaluate a new method of spinal specimen hydration through the vertebral body during in vitro testing in order to improve consistency of mechanical behaviour. Ovine lumbar anterior column units were prepared for testing. Half of the specimens were sprayed with Ringerʹs solution and wrapped in plastic foil. The remainder received an additional saline infusion into the centre of each vertebral body. Three consecutive compression steps were applied by a hydraulic testing machine. Average forces within four sectors of the relaxation curves were compared. ng saline infusion improves the consistency of consecutive relaxation curves. Differences between consecutive relaxation curves were less than those for standard hydration. The forces at the beginning of the relaxation curve were also lower for the infusion method. The standard deviation between specimens of each group was lower for saline infusion of vertebrae. Hence, the new method leads to more consistent in vitro testing conditions.
Keywords :
in vitro testing , Inhibited fluid flow , Spine biomechanics , New hydration method , intervertebral disc
Journal title :
Medical Engineering and Physics
Serial Year :
2007
Journal title :
Medical Engineering and Physics
Record number :
1729539
Link To Document :
بازگشت