Title of article :
A computational framework to predict post-treatment outcome for gait-related disorders
Author/Authors :
Reinbolt، نويسنده , , Jeffrey A. and Haftka، نويسنده , , Raphael T. and Chmielewski، نويسنده , , Terese L. and Fregly، نويسنده , , Benjamin J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
10
From page :
434
To page :
443
Abstract :
Clinicians often use intuitive models based on clinical experience or regression models based on population studies to plan treatment of gait-related disorders. Because such models are constructed using data collected from previous patients, the predicted clinical outcome for a particular patient may not be reliable. We propose a new approach that uses computational models based on engineering mechanics to predict post-treatment outcome from pre-treatment movement data. The approach utilizes a four-phase optimization process built around a dynamic, patient-specific gait model. The first three phases calibrate the modelʹs joint, inertial, and control parameters, respectively, where the control parameters are weights in an optimization cost function that tracks the patientʹs pre-treatment gait motion and loads. The last phase predicts the patientʹs post-treatment gait pattern by performing a tracking optimization with the calibrated model modified to simulate the selected treatment. onstrate the approach by simulating how two treatments for knee osteoarthritis (OA) – gait modification and high tibial osteotomy (HTO) surgery – alter the external knee adduction torque for a specific patient. By performing multiple tracking optimizations, we calibrated the modelʹs parameter values to reproduce the patientʹs knee adduction torque curve for a toe out gait motion. When we performed a tracking optimization with the calibrated model using a modified footpath to simulate an increased stance width, the predicted reduction in both adduction torque peaks matched experimental results to within 4.8% error. When we performed a tracking optimization with the same model using modified leg geometry to simulate HTO surgery, the predicted reductions were consistent with published data. The approach requires further evaluation with a larger number of patients to determine its effectiveness for planning the treatment of gait-related disorders on a patient-specific basis.
Keywords :
High tibial osteotomy , Patient-specific , Knee adduction moment , optimization , Gait
Journal title :
Medical Engineering and Physics
Serial Year :
2008
Journal title :
Medical Engineering and Physics
Record number :
1729853
Link To Document :
بازگشت