Title of article :
Operating Experience with Oksid Gas Analyzers at Tyumen Cogeneration Power Station TETs-1
Author/Authors :
Ippolitov، I. I. نويسنده , , Buldakov، M. A. نويسنده , , Zhilitskii، V. F. نويسنده , , Karankevich، E. N. نويسنده , , Korolev، B. V. نويسنده , , Krainov، V. V. نويسنده , , Matrosov، I. I. نويسنده , , Tigeev، S. V. نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 1999
Pages :
-866
From page :
867
To page :
0
Abstract :
Four years of operating experience with "Oksid" gas analyzers at Tyumen cogeneration power station TETs-1 is described. These gas analyzers are used for the continuous monitoring of emissions of NOx into the atmosphere. Such monitoring enables the operators to keep track of the environmental characteristics of the process of fuel combustion. Continuous measurement of the concentration of the nitrogen oxide in the flue gases make it possible to go from calculations of the gross annual emissions of NOx to determining them from the actual concentrations of nitrogen oxide in the boilers.
Keywords :
ISE , Detection limit , Lipophilic anionci agents , Lipophilicity , Ternary complex , Potentioinctric selectivity
Journal title :
Thermal Engineering
Serial Year :
1999
Journal title :
Thermal Engineering
Record number :
17304
Link To Document :
بازگشت