• Title of article

    Induced damage zone in micro-fine dental finishing of a feldspathic porcelain

  • Author/Authors

    Song، نويسنده , , Xiao-Fei and Yin، نويسنده , , Ling، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    6
  • From page
    417
  • To page
    422
  • Abstract
    Intraoral adjustment of ceramic prostheses involving micro-finishing a feldspathic porcelain using very fine diamond burs was reported in Med Eng Phys 2008;30:856–864 with respect to finishing force, energy and surface integrity. The measured finishing forces were found to be very small. The remaining question is whether these small forces in the micro-dental finishing induced any subsurface damage to the porcelain. This paper addresses the finite element analysis (FEA) of the finishing-induced stresses and the depths of subsurface damage in micro-fine finishing. It also reports on the measurement of the subsurface damage using scanning electron microscopy (SEM). The results indicate that while finishing using fine diamond burs diminished subsurface damage, damage depths of smaller than 18 μm remained depending on the bur depth of cut and feed rate. These damages can only be minimized under very fine finishing conditions.
  • Keywords
    SUBSURFACE DAMAGE , FEA , Dental ceramics , Micro-finishing , stress field
  • Journal title
    Medical Engineering and Physics
  • Serial Year
    2010
  • Journal title
    Medical Engineering and Physics
  • Record number

    1730936