Title of article :
Deformation behavior of the iliotibial tract under different states of fixation
Author/Authors :
Steinke، نويسنده , , Hanno and Lingslebe، نويسنده , , Uwe and Bِhme، نويسنده , , Jِrg and Slowik، نويسنده , , Volker and Shim، نويسنده , , Vickie and Hنdrich، نويسنده , , Carsten and Hammer، نويسنده , , Niels، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
7
From page :
1221
To page :
1227
Abstract :
Background and objective iotibial tract (tract) is an important structure for the biomechanics of both the hip and knee joint. While a detailed characterization of its mechanical properties might help to better understand its specific role in the load transfer from the pelvis to femur and tibia, determination of those properties is complicated by its particular structure of thin fibers in the fresh state. Moreover, although the tracts mechanical properties are often derived from cadaveric material chemically fixed with either ethanol or formaldehyde, the influence of such fixation methods remains to be elucidated. Aim of this study was to determine Youngʹs modulus (tensile modulus, YM) of the tract. We hypothesized that either ethanol or formaldehyde fixation would significantly increase the YM compared to the tracts condition in a fresh state. al and methods cimens of tract were gained from donators. The ends of the probes were plastinated with resin creating a sharp interface between the clamp and the probe to prevent material slippage. The specimens were measured in their fresh state, under ethanol- and formaldehyde-fixed conditions and re-measured after rinsing with tap water. s of the fresh probes averaged 397.3 N/mm2 with a standard deviation (SD) of 151.5 N/mm2. The YM of the ethanol-fixed specimens was significantly higher (673.2 N/mm2, SD 328.5 N/mm2, p < 0.05). After rinsing with tap water, the YM decreased to 95% of the fresh condition value (377.4 N/mm2, SD 144.5 N/mm2, non-significant change from fresh). After formaldehyde fixation, the YM reached 490.3 N/mm2 (SD 143.0 N/mm2, p < 0.05). When the formaldehyde-fixed specimens were rinsed, the YM was 114% of the value of the fresh condition (452.6 N/mm2, SD 115.1 N/mm2, non-significant change from fresh). sions tudy found a significant influence of the chemical fixation method on the YM of the IT tract. If such fixation is required, our results suggest using a treatment with ethanol and subsequent rinsing that results in minimal changes to the tracts YM. Furthermore, plastination of the ends of the specimens could be crucial to allow in vitro determination of valid YM of ligaments data that can then be integrated with confidence in further finite element analyses.
Keywords :
Ligament , Lower extremity , Youngיs modulus , Biomechanics , fixation , Formaldehyde , Finite elements , Iliotibial tract , pelvis
Journal title :
Medical Engineering and Physics
Serial Year :
2012
Journal title :
Medical Engineering and Physics
Record number :
1731826
Link To Document :
بازگشت