Title of article :
Fatigue testing of implantable specimens: Effect of sample size and branching on the dynamic fatigue properties of polyisobutylene-based biomaterials
Author/Authors :
Puskas، نويسنده , , Judit E. and Dos Santos، نويسنده , , Lucas M. and Fischer، نويسنده , , Frank and Gِtz، نويسنده , , Christian and El Fray، نويسنده , , Miroslawa and Altstنdt، نويسنده , , Volker and Tomkins، نويسنده , , Matthew، نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 2009
Pages :
7
From page :
591
To page :
597
Abstract :
In this paper we present the first results on the effect of specimen size and branching on the fatigue properties of polyisobutylene-based thermoplastic elastomers measured by the hysteresis method. It was verified that smaller specimens were inherently stronger as expected; at the same loading rate microdumbbells induced higher strain rates so they can be considered as the “worst case” scenario. Microdumbbells, which can be implanted into small animals for in vivo studies, were used for dynamic fatigue testing of linear poly(styrene-b-isobutylene-b-styrene) triblock copolymers (L_SIBS) in comparison with long-chain branched (tree-like or dendritic) versions (D_SIBS). In dynamic stress relaxation studies, D_SIBS performed better than L_SIBS. Simulated physiological conditions had negligible effect on the dynamic properties.
Keywords :
In vitro tensile testing , Poly(styrene-b-isobutylene-b-styrene) SIBS , Long chain branching
Journal title :
Polymer
Serial Year :
2009
Journal title :
Polymer
Record number :
1732528
Link To Document :
بازگشت