Title of article :
The Accuracy of Water Level Measurements in Steam Generators at Nuclear Power Stations
Author/Authors :
Demchenko، V. A. نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 1999
Pages :
-142
From page :
143
To page :
0
Abstract :
Questions of measuring the water level in steam generators at nuclear power stations by means of small-base hydrostatic level gages are considered. It is shown that the standard level gages of steam generators are suited for use in a nonboiling liquid. This leads to a significant error in measuring the water level at working loads. A scale for a small-base water-level gage suited for various loads on the steam generator was calculated, and a pattern for calibrating such a scale was proposed.
Keywords :
structure & design , maintenance & inspection , Buildings , structural frameworks
Journal title :
Thermal Engineering
Serial Year :
1999
Journal title :
Thermal Engineering
Record number :
17332
Link To Document :
بازگشت