• Title of article

    Fractional subpixel diffusion and fuzzy logic approach for ultrasound speckle reduction

  • Author/Authors

    Zhang، نويسنده , , Yingtao and Cheng، نويسنده , , H.D. and Tian، نويسنده , , Jiawei and Huang، نويسنده , , Jianhua and Tang، نويسنده , , Xianglong، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    9
  • From page
    2962
  • To page
    2970
  • Abstract
    Speckle is the dominant source of noise in ultrasound imaging and is a kind of multiplicative noise. It is difficult to design a filter to remove speckle effectively. In this paper, a novel fuzzy subpixel fractional partial difference (FSFPD) for ultrasound speckle reduction is proposed. Euler–Lagrange equation acts as an increasing function of the fractional derivativeʹs absolute value of the image intensity function. The fractional order partial difference is computed in the frequency and fuzzy domain with subpixel precision. We test the proposed method on both synthetic and real breast ultrasound (BUS) images. The comparisons of the experimental results show that the proposed method can preserve edges and structural details of ultrasound images well while removing speckle noise. In addition, the filtered images are assessed and evaluated by radiologists using double blind method. The results demonstrate that the discrimination rate of breast cancers has been highly improved after employing the proposed method.
  • Keywords
    speckle reduction , Breast ultrasound (BUS) imaging , Fuzzy entropy , Anisotropic Diffusion , Subpixel , FSFPD (fuzzy subpixel fractional partial difference)
  • Journal title
    PATTERN RECOGNITION
  • Serial Year
    2010
  • Journal title
    PATTERN RECOGNITION
  • Record number

    1733666