Title of article :
Percutaneous Mitral Repair With the MitraClip System: Safety and Midterm Durability in the Initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) Cohort
Author/Authors :
Feldman، نويسنده , , Ted and Kar، نويسنده , , Saibal and Rinaldi، نويسنده , , Michael and Fail، نويسنده , , Peter and Hermiller، نويسنده , , James and Smalling، نويسنده , , Richard and Whitlow، نويسنده , , Patrick L. and Gray، نويسنده , , William and Low، نويسنده , , Reginald and Herrmann، نويسنده , , Howard C. and Lim، نويسنده , , Scott A. Foster، نويسنده , , Elyse and Glower، نويسنده , , Donald، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
Objectives
ertook a prospective multicenter single-arm study to evaluate the feasibility, safety, and efficacy of the MitraClip system (Evalve Inc., Menlo Park, California).
ound
valve repair for mitral regurgitation (MR) has been performed by the use of a surgically created double orifice. Percutaneous repair based on this surgical approach has been developed by use of the Evalve MitraClip device to secure the mitral leaflets.
s
ts with 3 to 4+ MR were selected in accordance with the American Heart Association/American College of Cardiology guidelines for intervention and a core echocardiographic laboratory.
s
l of 107 patients were treated. Ten (9%) had a major adverse event, including 1 nonprocedural death. Freedom from clip embolization was 100%. Partial clip detachment occurred in 10 (9%) patients. Overall, 79 of 107 (74%) patients achieved acute procedural success, and 51 (64%) were discharged with MR of ≤1+. Thirty-two patients (30%) had mitral valve surgery during the 3.2 years after clip procedures. When repair was planned, 84% (21 of 25) were successful. Thus, surgical options were preserved. A total of 50 of 76 (66%) successfully treated patients were free from death, mitral valve surgery, or MR >2+ at 12 months (primary efficacy end point). Kaplan-Meier freedom from death was 95.9%, 94.0%, and 90.1%, and Kaplan-Meier freedom from surgery was 88.5%, 83.2%, and 76.3% at 1, 2, and 3 years, respectively. The 23 patients with functional MR had similar acute results and durability.
sions
aneous repair with the MitraClip system can be accomplished with low rates of morbidity and mortality and with acute MR reduction to < 2+ in the majority of patients, and with sustained freedom from death, surgery, or recurrent MR in a substantial proportion (EVEREST I; NCT00209339. EVEREST II; NCT00209274).
Keywords :
percutaneous valve therapy , Mitral regurgitation , mitral repair
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)