Title of article :
Percutaneous Pacemaker and Implantable Cardioverter-Defibrillator Lead Extraction in 100 Patients With Intracardiac Vegetations Defined by Transesophageal Echocardiogram
Author/Authors :
Jill Grammes، نويسنده , , Jon A. and Schulze، نويسنده , , Christopher M. and Al-Bataineh، نويسنده , , Mohammad and Yesenosky، نويسنده , , George A. and Saari، نويسنده , , Christine S. and Vrabel، نويسنده , , Michelle J. and Horrow، نويسنده , , Jay and Chowdhury، نويسنده , , Mashiul and Fontaine، نويسنده , , John M. and Kutalek، نويسنده , , Steven P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
9
From page :
886
To page :
894
Abstract :
Objectives cribe the feasibility, safety, and clinical outcomes of percutaneous lead extraction in patients at a tertiary care center who had intracardiac vegetations identified by transesophageal echocardiogram. ound ion in the presence of intracardiac devices is a problem of considerable morbidity and mortality. Patients with intracardiac vegetations are at high risk for complications related to extraction and protracted clinical courses. Historically, lead extraction in this cohort has been managed by surgical thoracotomy. s lyzed percutaneous lead extractions performed from January 1991 to September 2007 in infected patients with echocardiographic evidence of intracardiac vegetations, followed by a descriptive and statistical analysis. s l of 984 patients underwent extraction of 1,838 leads; local or systemic infection occurred in 480 patients. One hundred patients had intracardiac vegetations identified by transesophageal echocardiogram, and all underwent percutaneous lead extraction (215 leads). Mean age was 67 years. Median extraction time was 3 min per lead; median implant duration was 34 months. During the index hospitalization, a new device was implanted in 54 patients at a median of 7 days after extraction. Post-operative 30-day mortality was 10%; no deaths were related directly to the extraction procedure. sions ts with intracardiac vegetations identified on transesophageal echocardiogram can safely undergo complete device extraction using standard percutaneous lead extraction techniques. Permanent devices can safely be reimplanted provided blood cultures remain sterile. The presence of intracardiac vegetations identifies a subset of patients at increased risk for complications and early mortality from systemic infection despite device extraction and appropriate antimicrobial therapy.
Keywords :
Pacemaker , percutaneous lead extraction , vegetations , Endocarditis , Cardioverter-defibrillator , cardiac device infection , intravascular infection
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2010
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1746922
Link To Document :
بازگشت