Title of article :
Serum Markers of Collagen Turnover Predict Future Shocks in Implantable Cardioverter-Defibrillator Recipients With Dilated Cardiomyopathy on Optimal Treatment
Author/Authors :
Kanoupakis، نويسنده , , Emmanuel M. and Manios، نويسنده , , Emmanuel G. and Kallergis، نويسنده , , Eleftherios M. and Mavrakis، نويسنده , , Hercules E. and Goudis، نويسنده , , Christos A. and Saloustros، نويسنده , , Ilias G. and Milathianaki، نويسنده , , Maria E. and Chlouverakis، نويسنده , , Gregory I. and Vardas، نويسنده , , Panos E.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
7
From page :
2753
To page :
2759
Abstract :
Objectives estigated prospectively whether serum markers of collagen turnover could be used as predictors for the occurrence of malignant ventricular arrhythmias in patients with nonischemic dilated cardiomyopathy (NIDC) who had received an implantable cardioverter-defibrillator (ICD) for primary prevention. ound ellular matrix alterations in NIDC might provide electrical heterogeneity, thus potentially contributing to the occurrence of ventricular arrhythmia and subsequent sudden cardiac death (SCD). s C-terminal propeptide of collagen type-I, C-terminal telopeptide of collagen type-I, matrix metalloproteinase (MMP)-1, and tissue inhibitor of MMP-1 were measured as markers of collagen synthesis and degradation in 70 patients with mild to moderate symptomatic heart failure due to NIDC with left ventricular ejection fraction <35%, who received an ICD for primary prevention of SCD. Patients were evaluated for any appropriate ICD delivered therapy, whether shock or antitachycardia pacing, during a 1-year follow-up period. s riate device therapies were delivered in 14 of the 70 patients during the follow-up period, with antitachycardia pacing in 2, antitachycardia pacing with shocks in 4, and shocks in 8. Pre-implantation serum concentrations of C-terminal telopeptide of collagen type-I levels were significantly higher in patients who had appropriate ICD-delivered therapy than in those who did not have any therapy (0.46 ± 0.19 ng/ml vs. 0.19 ± 0.07 ng/ml, p < 0.001, respectively). The same was true for baseline MMP-1 and tissue inhibitor of MMP-1 (27.7 ± 1.6 ng/ml vs. 24.1 ± 2.5 ng/ml, p < 0.001, and 89 ± 14 ng/ml vs. 58 ± 18 ng/ml, p = 0.008, respectively). sions maximum benefit is to be achieved from ICD therapy in NIDC patients for the primary prevention of SCD, a more precise risk stratification is required. As extracellular matrix alterations affect the arrhythmogenic substrate in NIDC, we observed that serum markers of collagen turnover could predict arrhythmic events in ICD recipients.
Keywords :
Collagen , defibrillators , Fibrosis , Ventricular arrhythmias
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2010
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1747728
Link To Document :
بازگشت