Title of article :
Device-Detected Atrial Tachyarrhythmias Predict Adverse Outcome in Real-World Patients With Implantable Biventricular Defibrillators
Author/Authors :
Santini، نويسنده , , Massimo and Gasparini، نويسنده , , Maurizio and Landolina، نويسنده , , Maurizio and Lunati، نويسنده , , Maurizio and Proclemer، نويسنده , , Alessandro and Padeletti، نويسنده , , Luigi and Catanzariti، نويسنده , , Domenico and Molon، نويسنده , , Giulio and Botto، نويسنده , , Giovanni Luca and La Rocca، نويسنده , , Laura and Grammatico، نويسنده , , Andrea and Boriani، نويسنده , , Giuseppe، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
Objectives
rpose of this analysis was to evaluate the correlation between atrial tachycardia (AT) or atrial fibrillation (AF) and clinical outcomes in heart failure (HF) patients implanted with a cardiac resynchronization therapy defibrillator (CRT-D).
ound
patients, AT and AF have high prevalence and are associated with compromised hemodynamic function.
s
four Italian cardiological centers followed up 1,193 patients who received a CRT-D according to current guidelines for advanced HF, New York Heart Association functional class ≥II, left ventricular ejection fraction ≤35%, and QRS complex ≥120 ms. All patients were in sinus rhythm at implant.
s
a median follow-up period of 13 months, AT/AF >10 min occurred in 361 of 1,193 (30%) patients. The composite end point (deaths or HF hospitalizations) occurred in 174 of 1,193 (14.6%). Multivariate time-dependent Cox regression analyses showed that composite end point risk was higher among patients with device-detected AT/AF (hazard ratio [HR]: 2.16, p = 0.032), New York Heart Association functional class III or IV compared with II (HR: 2.09, p = 0.002), and absence of beta-blockers (HR: 1.36, p = 0.036). Furthermore, the composite end point risk was inversely associated with left ventricular ejection fraction (HR: 1.04, p = 0.045), increasing by a factor of 4% for each 1% decrease in left ventricular ejection fraction.
sions
patients with CRT-D, device-detected AT/AF is associated with a worse prognosis. Continuous device diagnostics monitoring and Web-based alerts may inform the physician of AT/AF occurrences and identify patients at risk of cardiac deterioration or patients with suboptimal rate or rhythm control. (Italian ClinicalService Project; NCT01007474)
Keywords :
Cardiac resynchronization , Heart Failure , defibrillator , atrial tachyarrhythmias , Clinical outcomes
Journal title :
JACC (Journal of the American College of Cardiology)