Title of article :
The Percutaneous Ventricular Assist Device in Severe Refractory Cardiogenic Shock
Author/Authors :
Kar، نويسنده , , Biswajit and Gregoric، نويسنده , , Igor D. and Basra، نويسنده , , Sukhdeep S. and Idelchik، نويسنده , , Gary M. and Loyalka، نويسنده , , Pranav، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
9
From page :
688
To page :
696
Abstract :
Objectives luated the efficacy and safety of the percutaneous ventricular assist device (pVAD) in patients in severe refractory cardiogenic shock (SRCS) despite intra-aortic balloon pump (IABP) and/or high-dose vasopressor support. ound s associated with substantial mortality despite IABP counterpulsation. Until recently, there was no rapid, minimally invasive means of providing increased hemodynamic support in SRCS. s l of 117 patients with SRCS implanted with TandemHeart pVAD (CardiacAssist, Inc., Pittsburgh, Pennsylvania) were studied, of whom 56 patients (47.9%) underwent active cardiopulmonary resuscitation immediately before or at the time of implantation. Data was collected regarding clinical characteristics, hemodynamics, and laboratory values. s patients had ischemic and 37 patients had nonischemic cardiomyopathy. The average duration of support was 5.8 ± 4.75 days. After implantation, the cardiac index improved from median 0.52 (interquartile range [IQR]: 0.8) l/(min·m2) to 3.0 (IQR: 0.9) l/(min·m2) (p < 0.001). The systolic blood pressure and mixed venous oxygen saturation increased from 75 (IQR: 15) mm Hg to 100 (IQR: 15) mm Hg (p < 0.001) and 49 (IQR: 11.5) to 69.3 (IQR: 10) (p < 0.001), respectively. The urine output increased from 70.7 (IQR: 70) ml/day to 1,200 (IQR: 1,620) ml/day (p < 0.001). The pulmonary capillary wedge pressure, lactic acid level, and creatinine level decreased, respectively, from 31.53 ± 10.2 mm Hg to 17.29 ± 10.82 mm Hg (p < 0.001), 24.5 (IQR: 74.25) mg/dl to 11 (IQR: 92) mg/dl (p < 0.001), and 1.5 (IQR: 0.95) mg/dl to 1.2 (IQR: 0.9) mg/dl (p = 0.009). The mortality rates at 30 days and 6 months were 40.2% and 45.3%, respectively. sions AD rapidly reversed the terminal hemodynamic compromise seen in patients with SRCS refractory to IABP and vasopressor support.
Keywords :
Myocardial infarction , Heart Failure , Shock , Cardiopulmonary Resuscitation , assist devices , cardiomyopathy
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2011
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1749059
Link To Document :
بازگشت