• Title of article

    An investigation on the use of removal-diffusion theory for BNCT treatment planning: A method for determining proper removal-diffusion parameters

  • Author/Authors

    Albertson، B. J. نويسنده , , Blue، T. E. نويسنده , , Niemkiewicz، J. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    -1897
  • From page
    1898
  • To page
    0
  • Abstract
    This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an accurate calculation technique for determining absorbed dose distributions for the purpose of BNCT treatment planning. For a four-group, one-dimensional calculation in water, this method was used to determine values for the neutron scattering cross sections, neutron removal cross sections, neutron diffusion coefficients, and extrapolation distances. These values were then used in a one-dimensional DIF3D calculation. The results of the DIF3D calculation showed a maximum deviation of 2.5% from a MCNP calculation performed for the same geometry.
  • Keywords
    short circuit current , transient over voltage , Fault current limiter , power quality
  • Journal title
    MEDICAL PHYSICS
  • Serial Year
    2001
  • Journal title
    MEDICAL PHYSICS
  • Record number

    1752