Title of article
Micro-robotic deposition guidelines by a design of experiments approach to maximize fabrication reliability for the bone scaffold application
Author/Authors
Hoelzle، نويسنده , , David J. and Alleyne، نويسنده , , Andrew G. and Wagoner Johnson، نويسنده , , Amy J.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
16
From page
897
To page
912
Abstract
This work aims to facilitate the transition of micro-robotic deposition (μRD) technology from the research bench to a mass manufacturing environment. The bone scaffolding application is targeted; however, the evaluation process developed is applicable to multiple colloidal material systems, length scales, and structure architectures. A design of experiments (DoE) approach is used to develop statistical correlations between three manufacturing treatments (material calcination time, nozzle size, and deposition speed) and defined reliability metrics. All three selected treatments have a significant effect on structure quality. A longer material calcination time improves the deposition of internal features. Logically, a larger nozzle size decreases structural defects. However, an unexpected result is revealed by this study. Higher deposition speeds are shown to either significantly improve or have no effect on structure quality, permitting a decrease in manufacturing time without adverse consequences.
Keywords
process optimization , Micro-robotic deposition , Tissue engineering , ceramic processing
Journal title
Acta Biomaterialia
Serial Year
2008
Journal title
Acta Biomaterialia
Record number
1752512
Link To Document