• Title of article

    Micro-robotic deposition guidelines by a design of experiments approach to maximize fabrication reliability for the bone scaffold application

  • Author/Authors

    Hoelzle، نويسنده , , David J. and Alleyne، نويسنده , , Andrew G. and Wagoner Johnson، نويسنده , , Amy J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    16
  • From page
    897
  • To page
    912
  • Abstract
    This work aims to facilitate the transition of micro-robotic deposition (μRD) technology from the research bench to a mass manufacturing environment. The bone scaffolding application is targeted; however, the evaluation process developed is applicable to multiple colloidal material systems, length scales, and structure architectures. A design of experiments (DoE) approach is used to develop statistical correlations between three manufacturing treatments (material calcination time, nozzle size, and deposition speed) and defined reliability metrics. All three selected treatments have a significant effect on structure quality. A longer material calcination time improves the deposition of internal features. Logically, a larger nozzle size decreases structural defects. However, an unexpected result is revealed by this study. Higher deposition speeds are shown to either significantly improve or have no effect on structure quality, permitting a decrease in manufacturing time without adverse consequences.
  • Keywords
    process optimization , Micro-robotic deposition , Tissue engineering , ceramic processing
  • Journal title
    Acta Biomaterialia
  • Serial Year
    2008
  • Journal title
    Acta Biomaterialia
  • Record number