• Title of article

    Evaluation of the Second Generation of a Bioresorbable Everolimus-Eluting Vascular Scaffold for the Treatment of De Novo Coronary Artery Stenosis: 12-Month Clinical and Imaging Outcomes

  • Author/Authors

    Serruys، نويسنده , , Patrick W. and Onuma، نويسنده , , Yoshinobu and Dudek، نويسنده , , Dariusz and Smits، نويسنده , , Pieter C. and Koolen، نويسنده , , Jacques and Chevalier، نويسنده , , Bernard and de Bruyne، نويسنده , , Bernard and Thuesen، نويسنده , , Leif and McClean، نويسنده , , Dougal and van Geuns، نويسنده , , Robert-Jan and Windecker، نويسنده , , Stephan and Whitbourn، نويسنده , , Robert، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    11
  • From page
    1578
  • To page
    1588
  • Abstract
    Objectives m of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and not simply delayed by a few months. ound mproved scaffold design and modified manufacturing process of its polymer, the second iteration of ABSORB (BVS 1.1) has improved performance to prevent a scaffold area reduction at 6 months. s six patients were enrolled and received 57 ABSORB scaffolds. Quantitative coronary angiography, intravascular ultrasound (IVUS), analysis of radiofrequency backscattering, echogenicity and optical coherence tomography (OCT) were performed at baseline and at 12-month follow-up. s l the scaffold area remained unchanged with IVUS as well as with OCT, whereas the radiofrequency backscattering and the echogenicity of the struts decreased by 16.8% (p < 0.001) and 20% (p < 0.001), respectively; more specifically, the strut core area on OCT decreased by 11.4% (p = 0.003). Despite the absence of scaffold area loss, pharmacological vasomotion was restored. On an intention-to-treat basis, the angiographic late lumen loss amounted to 0.27 ± 0.32 mm with an IVUS relative decrease in minimal lumen area of 1.94% (p = 0.12), without significant changes in mean lumen area. The OCT at follow-up showed that 96.69% of the struts were covered and that malapposition, initially observed in 18 scaffolds was only detected at follow-up in 4 scaffolds. Two patients experienced peri-procedural and iatrogenic myocardial infarction, respectively, whereas 2 underwent repeat intervention, resulting in the major adverse cardiac event rate of 7.1% (4 of 56). sions -month performance of the second-generation ABSORB bioresorbable everolimus-eluting scaffold justifies the conduct of a randomized trial against current best standards. (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System [BVS EECSS] in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00856856)
  • Keywords
    bioresorbable scaffold , Coronary Artery Disease , intravascular ultrasound , optical coherence tomography , angiography
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2011
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    1752998