• Title of article

    Transapical Aortic Valve Implantation: Incidence and Predictors of Paravalvular Leakage and Transvalvular Regurgitation in a Series of 358 Patients

  • Author/Authors

    Unbehaun، نويسنده , , Axel and Pasic، نويسنده , , Miralem and Dreysse، نويسنده , , Stephan and Drews، نويسنده , , Thorsten and Kukucka، نويسنده , , Marian and Mladenow، نويسنده , , Alexander and Ivanitskaja-Kühn، نويسنده , , Ekaterina and Hetzer، نويسنده , , Roland and Buz، نويسنده , , Semih، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    11
  • From page
    211
  • To page
    221
  • Abstract
    Objectives m of this study was to evaluate the results when the surgical concept of not accepting intraprocedural paravalvular leakage was applied for transcatheter aortic valve implantation (TAVI). ound rgical strategy of conventional aortic valve replacement does not accept paraprosthetic leakage and requires immediate action to eliminate it. However, paravalvular leakage is the major concern after TAVI. s l of 358 patients underwent transapical TAVI with balloon-expandable prostheses. The modified procedural strategy consisted of precise positioning of the prosthesis using a modified TAVI technique and immediate additional intraprocedural treatment to eliminate relevant paravalvular leakage. s n redilation of the transcatheter valve was performed in 18 patients (5%), and additional second valves were implanted in 13 (4%). At the end of the procedure, 186 patients (52%) had no paravalvular or transvalvular regurgitation. In the remaining 172 patients, paravalvular leakage was observed in 113 (32%), transvalvular leakage in 47 (13%), and both in 12 (3%). Leakage was trace in 88 patients (25%), mild in 82 (23%), and moderate in 2 (0.6%). Multivariate analysis identified male sex, New York Heart Association functional class IV, and no previous aortic valve replacement as predictors of post-procedural leakage. Cumulative survival was not dependent on post-procedural regurgitation rate. Overall mortality was 5 ± 1% at 30 days, 14 ± 2% at 6 months, 17 ± 2% at 1 year, and 33 ± 4% at 2 years. sions dified procedural strategy of transapical TAVI with a balloon-expandable prosthesis was associated with a low incidence of relevant prosthetic regurgitation.
  • Keywords
    aortic regurgitation , Predictors , transcatheter aortic valve implantation
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2012
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number