Title of article :
Performance of 3-Dimensional Echocardiography in Measuring Left Ventricular Volumes and Ejection Fraction: A Systematic Review and Meta-Analysis
Author/Authors :
Dorosz، نويسنده , , Jennifer L. and Lezotte، نويسنده , , Dennis C. and Weitzenkamp، نويسنده , , David A. and Allen، نويسنده , , Larry A. and Salcedo، نويسنده , , Ernesto E.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
10
From page :
1799
To page :
1808
Abstract :
Objectives imary aim of this systematic review is to objectively evaluate the test performance characteristics of three-dimensional echocardiography (3DE) in measuring left ventricular (LV) volumes and ejection fraction (EF). ound e its growing use in clinical laboratories, the accuracy of 3DE has not been studied on a large scale. It is unclear if this technology offers an advantage over traditional two-dimensional (2D) methods. s rched for studies that compared LV volumes and EF measured by 3DE and cardiac magnetic resonance (CMR) imaging. A subset of those also compared standard 2D methods with CMR. We used meta-analyses to determine the overall bias and limits of agreement of LV end-diastolic volume (EDV), end-systolic volume (ESV), and EF measured by 3DE and 2D echocardiography (2DE). s -three studies (1,638 echocardiograms) were included. The pooled biases ± 2 SDs for 3DE were −19.1 ± 34.2 ml, −10.1 ± 29.7 ml, and − 0.6 ± 11.8% for EDV, ESV, and EF, respectively. Nine studies also included data from 2DE, where the pooled biases were −48.2 ± 55.9 ml, −27.7 ± 45.7 ml, and 0.1 ± 13.9% for EDV, ESV, and EF, respectively. In this subset, the difference in bias between 3DE and 2D volumes was statistically significant (p = 0.01 for both EDV and ESV). The difference in variance was statistically significant (p < 0.001) for all 3 measurements. sions dimensional echocardiography underestimates volumes and has wide limits of agreement, but compared with traditional 2D methods in these carefully performed studies, 3DE is more accurate for volumes and more precise in all 3 measurements.
Keywords :
real-time three-dimensional echocardiography , EJECTION FRACTION , left ventricular volumes , META-ANALYSIS , systematic review
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2012
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1753988
Link To Document :
بازگشت