Title of article :
Head-to-Head Comparison of Left Ventricular Function Assessment with 64-Row Computed Tomography, Biplane Left Cineventriculography, and Both 2- and 3-Dimensional Transthoracic Echocardiography: Comparison With Magnetic Resonance Imaging as the Reference S
Author/Authors :
Greupner، نويسنده , , Johannes and Zimmermann، نويسنده , , Elke and Grohmann، نويسنده , , Andrea and Dübel، نويسنده , , Hans-Peter and Althoff، نويسنده , , Till and Borges، نويسنده , , Adrian C. and Rutsch، نويسنده , , Wolfgang and Schlattmann، نويسنده , , Peter and Hamm، نويسنده , , Bernd and Dewey، نويسنده , , Marc، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
11
From page :
1897
To page :
1907
Abstract :
Objectives tudy was designed to compare the accuracy of 64-row contrast computed tomography (CT), invasive cineventriculography (CVG), 2-dimensional echocardiography (2D Echo), and 3-dimensional echocardiography (3D Echo) for left ventricular (LV) function assessment with magnetic resonance imaging (MRI). ound c function is an important determinant of therapy and is a major predictor for long-term survival in patients with coronary artery disease. A number of methods are available for assessment of function, but there are limited data on the comparison between these multiple methods in the same patients. s l of 36 patients prospectively underwent 64-row CT, CVG, 2D Echo, 3D Echo, and MRI (as the reference standard). Global and regional LV wall motion and ejection fraction (EF) were measured. In addition, assessment of interobserver agreement was performed. s e global EF, Bland-Altman analysis showed significantly higher agreement between CT and MRI (p < 0.005, 95% confidence interval: ±14.2%) than for CVG (±20.2%) and 3D Echo (±21.2%). Only CVG (59.5 ± 13.9%, p = 0.03) significantly overestimated EF in comparison with MRI (55.6 ± 16.0%). CT showed significantly better agreement for stroke volume than 2D Echo, 3D Echo, and CVG. In comparison with MRI, CVG—but not CT—significantly overestimated the end-diastolic volume (p < 0.001), whereas 2D Echo and 3D Echo significantly underestimated the EDV (p < 0.05). There was no significant difference in diagnostic accuracy (range: 76% to 88%) for regional LV function assessment between the 4 methods when compared with MRI. Interobserver agreement for EF showed high intraclass correlation for 64-row CT, MRI, 2D Echo, and 3D Echo (intraclass correlation coefficient >0.8), whereas agreement was lower for CVG (intraclass correlation coefficient = 0.58). sions CT may be more accurate than CVG, 2D Echo, and 3D Echo in comparison with MRI as the reference standard for assessment of global LV function.
Keywords :
computed tomography , Echocardiography , Left ventricular function , MAGNETIC RESONANCE IMAGING
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2012
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1754014
Link To Document :
بازگشت