• Title of article

    Radial Artery and Saphenous Vein Patency More Than 5 Years After Coronary Artery Bypass Surgery: Results From RAPS (Radial Artery Patency Study)

  • Author/Authors

    Deb، نويسنده , , Saswata and Cohen، نويسنده , , Eric A. and Singh، نويسنده , , Steve K. and Une، نويسنده , , Dai and Laupacis، نويسنده , , Andreas and Fremes، نويسنده , , Stephen E.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    8
  • From page
    28
  • To page
    35
  • Abstract
    Objectives rpose of this study was to present radial and saphenous vein graft (SVG) occlusion results more than 5 years following coronary artery bypass surgery. ound RAPS (Radial Artery Patency Study) study, complete graft occlusion was less frequent in radial artery compared with SVG 1 year post-operatively while functional occlusion (Thrombolysis In Myocardial Infarction flow grade 0, 1, 2) was similar. s l of 510 patients <80 years of age undergoing primary isolated nonemergent coronary artery bypass grafting with 3-vessel disease were initially enrolled in 9 Canadian centers. Target vessels for the radial artery and study SVG were the right and circumflex coronary arteries, which had >70% proximal stenosis. Within-patient randomization was performed; the radial artery was randomized to either the right or circumflex territory and the study SVG was used for the other territory. The primary endpoint was functional graft occlusion by invasive angiography at least 5 years following surgery. Complete graft occlusion by invasive angiography or computed tomography angiography was a secondary endpoint. s l of 269 patients underwent late angiography (234 invasive angiography, 35 computed tomography angiography) at a mean of 7.7 ± 1.5 years after surgery. The frequency of functional graft occlusion was lower in radial arteries compared with SVGs (28 of 234 [12.0%] vs. 46 of 234 [19.7%]; p = 0.03 by McNemarʹs test). The frequency of complete graft occlusion was also significantly lower in radial compared with SVGs (24 of 269 [8.9%] vs. 50 of 269 [18.6%]; p = 0.002). sions arteries are associated with reduced rates of functional and complete graft occlusion compared with SVGs more than 5 years following surgery. (Multicentre Radial Artery Patency Study: 5 Year Results; NCT00187356)
  • Keywords
    graft patency , Radial artery , RCT , Saphenous vein
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2012
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    1754187