Abtahi، Mehrnoosh نويسنده 1Department of Environmental Health Engineering, School of Public Health and Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran , , Naddafi، Kazem نويسنده Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran , , Mesdaghinia، Alireza نويسنده 1Center for Environmental Research and Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran 2National Institute of Health Research, Ministry of Health, Tehran, Iran , , Yaghmaeian، Kamyar نويسنده Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran , , Nabizadeh، Ramin نويسنده Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran , , Jaafarzadeh، Nematollah نويسنده Department of Environmental Health Engineering, School of Health, Ahvaz Jondishapour University of Medical Sciences, Ahvaz, Iran , , Rastkari، Noushin نويسنده , , Nazmara، Shahrokh نويسنده 1Center for Environmental Research and Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran , , Saeedi Goraghani، Hamid Reza نويسنده Ph.D. Student of Range Management, Department of Reclamation of Arid and Mountainous Regions, University of Tehran, Iran ,
Issue Information :
ماهنامه با شماره پیاپی 0 سال 2014
Pages :
7
From page :
1
To page :
7
Abstract :
The performance of a hybrid bubble column/biofilter (HBCB) bioreactor for the removal of dichloromethane (DCM) from waste gas streams was studied in continuous mode for several months. The HBCB bioreactor consisted of two compartments: bubble column bioreactor removing DCM from liquid phase and biofilter removing DCM from gas phase. Effect of inlet DCM concentration on the elimination capacity was examined in the DCM concentration range of 34–359 ppm with loading rates ranged from 2.2 to 22.8 g/m3.h and constant total empty bed retention time (EBRT) of 200 s. In the equal loading rates, the elimination capacity and removal efficiency of the biofilter were higher than the corresponding values of the bubble column bioreactor. The maximum elimination capacity of the HBCB bioreactor was determined to be 15.7 g/m3.h occurred in the highest loading rate of 22.8 g/m3.h with removal efficiency of 69%. The overall mineralization portion of the HBCB bioreactor was in the range of 72-79%. The mixed liquor acidic pH especially below 5.5 inhibited microbial activity and decreased the elimination capacity. Inhibitory effect of high ionic strength was initiated in the mixed liquor electrical conductivity of 12.2 mS/cm. This study indicated that the HBCB bioreactor could benefit from advantages of both bubble column and biofilter reactors and could remove DCM from waste gas streams in a better manner.
Journal title :
Iranian Journal of Environmental Health Science and Engineering (IJEHSE)
Serial Year :
2014
Journal title :
Iranian Journal of Environmental Health Science and Engineering (IJEHSE)
Record number :
1754382
Link To Document :
بازگشت