Fukushima، نويسنده , , Kenji and Bravo، نويسنده , , Paco E. and Higuchi، نويسنده , , Takahiro and Schuleri، نويسنده , , Karl H. and Lin، نويسنده , , Xiaoping and Abraham، نويسنده , , M. Roselle and Xia، نويسنده , , Jinsong and Mathews، نويسنده , , William B. and Dannals، نويسنده , , Robert F. and Lardo، نويسنده , , Albert C. and Szabo، نويسنده , , Zsolt and Bengel، نويسنده , , Frank M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
8
From page :
2527
To page :
2534
Abstract :
Objectives al of this study was to explore the feasibility of targeted imaging of the angiotensin II type 1 receptor (AT1R) in cardiac tissue, using clinical hybrid positron emission tomography/computed tomography (PET/CT). ound s an attractive imaging target due to its key role in various cardiac pathologies, including post-infarct left ventricular remodeling. s the novel AT1R ligand [11C]-KR31173, dynamic PET/CT was performed in young farm pigs under healthy conditions (n = 4) and 3 to 4 weeks after experimental myocardial infarction (n = 5). Ex vivo validation was carried out by immunohistochemistry and polymerase chain reaction. First-in-man application was performed in 4 healthy volunteers at baseline and under AT1R blocking. s lthy pigs, myocardial KR31173 retention was detectable, regionally homogeneous, and specific for AT1R, as confirmed by blocking experiments. Metabolism in plasma was low (85 ± 2% of intact tracer after 60 min). After myocardial infarction, KR31173 retention, corrected for regional perfusion, revealed AT1R up-regulation in the infarct area relative to remote myocardium, whereas retention was elevated in both regions when compared with myocardium of healthy controls (8.7 ± 0.8% and 7.1 ± 0.3%/min vs. 5.8 ± 0.4%/min for infarct and remote, respectively, vs. healthy controls; p < 0.01 each). Postmortem analysis confirmed AT1R up-regulation in remote and infarct tissue. First-in-man application was safe, and showed detectable and specific myocardial KR31173 retention, albeit at a lower level than pigs (left ventricular average retention: 1.2 ± 0.1%/min vs. 4.4 ± 1.2%/min for humans vs. pigs; p = 0.04). sions asive imaging of cardiac AT1R expression is feasible using clinical PET/CT technology. Results provide a rationale for broader clinical testing of AT1R-targeted molecular imaging.
Keywords :
Renin-Angiotensin System , Angiotensin receptor , molecular imaging , Myocardial infarction , Positron emission tomography
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2012
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1755371
Link To Document :
بازگشت