Title of article :
Optimization Conditions For Determination of Cosmetic Preservatives using Ion-Exclusion Chromatography
Author/Authors :
Sid Kalal، H نويسنده NFRS, Nuclear Science and Technology Institute, AEOI, P. O. Box 11365-3486, Tehran, Iran , , Rafiei، J نويسنده NFRS, Nuclear Science and Technology Institute, AEOI, P. O. Box 11365-3486, Tehran, Iran , , Bani، F نويسنده Institute of Biochemistry & Biophysics (IBB), University of Tehran, Tehran, Iran , , Khanchi، A R نويسنده NFRS, Nuclear Science and Technology Institute, AEOI, P. O. Box 11365-3486, Tehran, Iran , , Hoveidi، H نويسنده Graduate Faculty of Environment, University of Tehran, Tehran,Iran ,
Issue Information :
فصلنامه با شماره پیاپی سال 2010
Pages :
8
From page :
289
To page :
296
Abstract :
An ion chromatography (IC) method for simultaneous determination of benzoic, salicylic and sorbic acids was developed. In this method the samples were purified by solid-phase extraction. The analytes were then eluted with methanol from C18 cartridge. The separation was performed on ion-exclusion column by an isocratic elution with 0.25 mmol /L sulfuric acid solution containing 20% (v/v) acetone as elute. The calibration curves showed good linearity with suppressed conductivity detection.Under this condition, separation of the three components was achieved in less than 23 min. The detection limit calculated as the concentration corresponding to three times the background noise, was 0.1, 0.15 and 0.2 mg/ L for benzoic acid, salicylic acid and sorbic acid respectively. The method was successfully applied to analysis of various cosmetic products.
Journal title :
International Journal of Environmental Research(IJER)
Serial Year :
2010
Journal title :
International Journal of Environmental Research(IJER)
Record number :
1756029
Link To Document :