Title of article :
Quality of Life Assessment in the Randomized PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) Trial of Patients at Risk for Stroke With Nonvalvular Atrial
Author/Authors :
Alli، نويسنده , , Oluseun and Doshi، نويسنده , , Shepal and Kar، نويسنده , , Saibal and Reddy، نويسنده , , Vivek and Sievert، نويسنده , , Horst and Mullin، نويسنده , , Chris and Swarup، نويسنده , , Vijay and Whisenant، نويسنده , , Brian and Holmes Jr، نويسنده , , David، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
Objectives
tudy sought to assess quality of life parameters in a subset of patients enrolled in the PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) trial.
ound
OTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) trial demonstrated that in patients with nonvalvular atrial fibrillation (AF) and CHADS2 (congestive heart failure, hypertension, age, diabetes mellitus, and prior stroke, transient ischemic attack, or thromboembolism) score ≥1, a left atrial appendage closure device is noninferior to long-term warfarin for stroke prevention. Given this equivalency, quality of life (QOL) indicators are an important metric for evaluating these 2 different strategies.
s
ing the Short-Form 12 Health Survey, version 2, measurement tool was obtained at baseline and 12 months in a subset of 547 patients in the PROTECT AF trial (361 device and 186 warfarin patients). The analysis cohort consisted of patients for whom either paired quality of life data were available after 12 months of follow-up or for patients who died.
s
he device, the total physical score improved in 34.9% and was unchanged in 29.9% versus warfarin in whom 24.7% were improved and 31.7% were unchanged (p = 0.01). Mental health improvement occurred in 33.0% of the device group versus 22.6% in the warfarin group (p = 0.06). There was a significant improvement in QOL in patients randomized to device for total physical score, physical function, and in physical role limitation compared to control. There were significant differences in the change in total physical score among warfarin naive and not–warfarin naive subgroups in the device group compared to control, but larger gains were seen with the warfarin naive subgroup with a 12-month change of 1.3 ± 8.8 versus −3.6 ± 6.7 (p = 0.0004) device compared to warfarin.
sions
ts with nonvalvular AF at risk for stroke treated with left atrial appendage closure have favorable QOL changes at 12 months versus patients treated with warfarin. (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation [WATCHMAN PROTECT]; NCT00129545)
Keywords :
left atrial appendage occlusion , Stroke prevention , atrial fibrillation , Health-related quality of life , Warfarin
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)