Title of article :
Impact of Baseline Heart Failure Burden on Post-Implantable Cardioverter-Defibrillator Mortality Among Medicare Beneficiaries
Author/Authors :
Chen، نويسنده , , Chih-Ying and Stevenson، نويسنده , , Lynne Warner and Stewart، نويسنده , , Garrick C. and Seeger، نويسنده , , John D. and Williams، نويسنده , , Lauren and Jalbert، نويسنده , , Jessica J. and Setoguchi، نويسنده , , Soko، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
9
From page :
2142
To page :
2150
Abstract :
Objectives tudy sought to assess the impact of baseline heart failure (HF) burden on survival with primary implantable cardioverter-defibrillator (ICD) among Medicare recipients. ound al after primary ICD implantation may differ between trial and Medicare populations. s g data from the CMS (Centers for Medicare and Medicaid Services) ICD registry and the Medicare files (2005 to 2009), we identified primary ICD recipients age ≥66 years with ejection fraction ≤35%. Number of previous HF hospitalizations (prev-HF-hosp) and length of hospitalization prior to implantation were used to define HF burden. Crude all-cause mortality was estimated. Adjusted hazard ratios (HR) were derived from Cox models. s 974 ICD recipients (73% men, 88% white, mean age 75 years), 11,876 died (average follow-up = 1.4 years), with 3-year mortality of 31%. Among patients with no prev-HF-hosp, 3-year mortality was 27% compared with 63% in those with ≥3 prev-HF-hosp (adjusted HR: 1.8). Among patients with same-day implantation, 3-year mortality was 25% compared with 53% in those with >1-week hospitalization days prior to implantation (adjusted HR: 1.9). Mortality at 3-year follow-up among the 31,685 ICD recipients with no prev-HF-hosp and same-day implantation (low HF burden) was similar to that in trials (22%). sions one-third of Medicare ICD recipients died within 3 years, reflecting a population with more advanced age and disease than seen in trial populations for primary prevention ICD. Nearly one-half of Medicare recipients had a low HF burden and had a survival similar to trial ICD recipients. Future research is warranted to understand the effectiveness of primary ICD implantation among Medicare beneficiaries with heavy HF burdens.
Keywords :
Heart Failure , implantable cardioverter-defibrillator , mortality , Primary Prevention
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2013
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1756680
Link To Document :
بازگشت