Title of article :
Survival After Shock Therapy in Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Therapy-Defibrillator Recipients According to Rhythm Shocked: The ALTITUDE Survival by Rhythm Study
Author/Authors :
Powell، نويسنده , , Brian D. and Saxon، نويسنده , , Leslie A. and Boehmer، نويسنده , , John P. and Day، نويسنده , , John D. and Gilliam III، نويسنده , , F. Roosevelt and Heidenreich، نويسنده , , Paul A. Howard-Jones، نويسنده , , Paul W. and Rousseau، نويسنده , , Matthew J. and Hayes، نويسنده , , David L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
6
From page :
1674
To page :
1679
Abstract :
Objectives tudy sought to determine if the risk of mortality associated with inappropriate implantable cardioverter-defibrillator (ICD) shocks is due to the underlying arrhythmia or the shock itself. ound delivered from ICDs are associated with an increased risk of mortality. It is unknown if all patients who experience inappropriate ICD shocks have an increased risk of death. s luated survival outcomes in patients with an ICD and a cardiac resynchronization therapy defibrillator enrolled in the LATITUDE remote monitoring system (Boston Scientific Corp., Natick, Massachusetts) through January 1, 2010. First shock episode rhythms from 3,809 patients who acutely survived the initial shock were adjudicated by 7 electrophysiologists. Patients with a shock were matched to patients without a shock (n = 3,630) by age at implant, implant year, sex, and device type. s an age of the study group was 64 ± 13 years, and 78% were male. Compared with no shock, there was an increased rate of mortality in those who received their first shock for monomorphic ventricular tachycardia (hazard ratio [HR]: 1.65, p < 0.0001), ventricular fibrillation/polymorphic ventricular tachycardia (HR: 2.10, p < 0.0001), and atrial fibrillation/flutter (HR: 1.61, p = 0.003). In contrast, mortality after first shocks due to sinus tachycardia and supraventricular tachycardia (HR: 0.97, p = 0.86) and noise/artifact/oversensing (HR: 0.91, p = 0.76) was comparable to that in patients without a shock. sions ed with no shock, those who received their first shock for ventricular rhythms and atrial fibrillation had an increased risk of death. There was no significant difference in survival after inappropriate shocks for sinus tachycardia or noise/artifact/oversensing. In this study, the adverse prognosis after first shock appears to be more related to the underlying arrhythmia than to an adverse effect from the shock itself.
Keywords :
atrial fibrillation , cardiac resynchronization therapy , implantable cardioverter defibrillators , Ventricular Tachycardia
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2013
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1757575
Link To Document :
بازگشت