Title of article :
Potentiometric studies of the rutile–water interface: hydrogen-electrode concentration-cell versus glass-electrode titrations
Author/Authors :
Ridley، نويسنده , , Moira K. and Machesky، نويسنده , , Michael L. and Palmer، نويسنده , , Donald A. and Wesolowski، نويسنده , , David J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
14
From page :
295
To page :
308
Abstract :
This paper represents a comparison of surface protonation studies of rutile in NaCl media obtained using a conventional glass-electrode autotitrator system from 10 to 50 °C, and hydrogen-electrode concentration cells from 25 to 250 °C [J. Colloid Interface Sci., 200 (1998) 298]. Experimental conditions were matched as closely as possible between the two techniques, permitting a direct comparison of the results. Values for the pH of zero net proton charge (pHznpc) of the rutile surface obtained at 10 and 35 °C were consistent with the temperature trends observed previously using hydrogen-electrode concentration cells. The pHznpc of rutile decreases systematically from 5.7 to 4.2 as temperature increases from 10 to 250 °C. Moreover, the experimentally determined pHznpc values agree with independent estimates of the pH at the pristine point of zero charge (pHznpc) calculated from an extension of the revised Multi-Site Complexation (MUSIC) Model of Hiemstra et al. [J. Colloid Interface Sci., 184 (1996) 680]. Surface protonation curves obtained from the glass-electrode titration results were rationalized using surface protonation constants derived from the MUSIC Model, in conjunction with a Basic Stern representation of the electrical double layer (EDL) structure. Best-fit parameters (Stern layer capacitance values, and electrolyte cation and anion binding constants) are consistent with those obtained from fits to titration curves obtained using hydrogen-electrode concentration cells at 25 and 50 °C. Consequently, this comparison demonstrates that independent conventional glass-electrode and hydrogen-electrode concentration cell titrations provide completely compatible results despite the intrinsic differences in the two techniques (pH calibration, equilibration times, stirring rates, gas phase composition, etc).
Keywords :
Rutile , potentiometric titrations , Glass-electrode , Hydrogen-electrode concentration cell , Surface protonation , Point of zero charge
Journal title :
Colloids and Surfaces A Physicochemical and Engineering Aspects
Serial Year :
2002
Journal title :
Colloids and Surfaces A Physicochemical and Engineering Aspects
Record number :
1770775
Link To Document :
بازگشت