Title of article
Digital flow control of electroosmotic pump: Onsager coefficients and interfacial parameters determination
Author/Authors
Xu، نويسنده , , Zuli and Miao، نويسنده , , Jianying and Wang، نويسنده , , Ning and Wen، نويسنده , , Weijia and Sheng، نويسنده , , Ping، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
440
To page
445
Abstract
Electroosmosis and streaming potential are two complementary electrokinetic processes related by the Onsager relation. In particular, an electroosmotic pump (EOP) is potentially useful for a variety of engineering and bio-related applications. By fabricating samples consisting of dry-etched cylindrical pores (50 μm in length and 3.5 μm in diameter) on silicon wafers, we demonstrate that the use of digital control via voltage pulses can resolve the flow regulation and stability issues associated with the EOP, so that the intrinsic characteristics of the porous sample medium may be revealed. Through the consistency of the measured electroosmosis (EO) and the streaming potential (SP) coefficients as required by the Onsager relation, we deduce the zeta potential and the surface conductivity, both physical parameters pertaining to the liquid–solid interface.
Keywords
D. Electroosmotic pump , E. Digital flow control , D. Streaming potential , D. Onsager relation
Journal title
Solid State Communications
Serial Year
2011
Journal title
Solid State Communications
Record number
1792077