Title of article :
Nested Polymerase Chain Reaction for Mycobacterium tuberculosis DNA Detection in Aqueous and Vitreous of Patients with Uveitis
Author/Authors :
Ortega-Larrocea، نويسنده , , Gabriela and Bobadilla-del-Valle، نويسنده , , Miriam and Ponce-de-Leَn، نويسنده , , Alfredo and Sifuentes-Osornio، نويسنده , , José، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
4
From page :
116
To page :
119
Abstract :
Background ulosis may be a lethal disease. Its ocular manifestations are commonly associated with severe difficulties in diagnosis and therapy; furthermore, it may cause blindness. DNA amplification methods may allow early detection of small amounts of Mycobacterium tuberculosis DNA to afford the possibility of prompt diagnosis. We evaluated a nested polymerase chain reaction (nPCR) assay for detection of Mycobacterium tuberculosis DNA in aqueous and vitreous. s ase-control study, 22 cases of diagnosed TB uveitis (three HIV-infected patients) and 38 controls (18 HIV-infected patients) with other types of uveitis (syphilis, nine; cytomegalovirus, seven; toxoplasmosis, five; herpes simplex, one; autoimmune vasculitis, eight; Vogt-Koyanagi-Harada, four; pars planitis, one; serpinginous choroiditis, one; Wegener granulomatosis, one; and Fuchs iridocyclitis, one studied). Samples from aqueous or vitreous were cultured and analyzed by nPCR for presence of M. tuberculosis nucleic acids. We used two sets of primers corresponding to IS6110 region coding for 219 bp and 123 bp DNA sequences. s s were confirmed by Southern blot. All samples were tested by PCR simultaneously for Herpes simplex I, Herpes zoster, cytomegalovirus (CMV) and Toxoplasma gondii. nPCR was positive in 17 cases (77.2%) and only in three controls (8.8%) p = 0.022. All cultures were negative. Southern blot confirmed all positive nPCR tests. According to our definition of cases, there were five false negative results: two in patients with pulmonary tuberculosis; two in patients with tuberculous lymphadenitis, and one with positive skin test and hematuria. There were three cases considered false positives for nPCR: one with autoimmune vasculitis, and two with toxoplasmic uveitis. sions or TB in ocular fluids was positive in the majority of cases of ocular TB. This method is useful in early confirmation of ocular tuberculosis.
Keywords :
diagnosis , PCR , Ocular tuberculosis
Journal title :
Archives of Medical Research
Serial Year :
2003
Journal title :
Archives of Medical Research
Record number :
1794952
Link To Document :
بازگشت